ePOWER


ENERDRIVE EPOWER EN3DC40+

ENERDRIVE EPOWER EN3DC40+

    FEATURES:

    • TWO TOTALLY INDEPENDENT DC INPUTS FOR BOTH ENGINE AND SOLAR REGULATION CHARGING ONE HOUSE BATTERY BANK OUTPUT.
    • DC M6 SCREW TERMINALS THAT WILL ALLOW FOR LARGE BATTERY CABLE CONNECTION BETWEEN ALL SOURCES.
    • A DEDICATED MAXIMUM POWER POINT (MPPT) SOLAR REGULATOR.
    • THE SAME BATTERY ALGORITHMS AS INCLUDED IN OUR AC MAINS EPOWER BATTERY CHARGER. GEL, AGM, FLOODED, LITHIUM AND THE ABILITY TO CREATE A FULL CUSTOM PROFILE.
    • VEHICLE INPUT ALLOWS FOR EITHER 12 OR 24V AND A MAXIMUM SOLAR INPUT OF 45V/800W
    • 40A+ OUTPUT UP TO 40+°C WITH THERMO CONTROLLED FAN COOLING.
    • FULLY PROGRAMMABLE LCD DISPLAY TO SHOW WHICH SOURCE IS CHARGING THE BATTERY ALONG WITH CHARGER STATUS, VOLTAGE AND AMPERAGE.
    • TEMPERATURE SENSOR INCLUDED WITH CHARGER FOR MORE ACCURATE BATTERY CHARGING.

     

    SPECIFICATIONS:

    • OUTPUT VOLTAGE: 12V NOMINAL (8.0V MIN)
    • OUTPUT CURRENT (MAXIMUM): 40A ~ 50A
    • OUTPUT POWER: 775W
    • SELECTABLE BATTERY TYPE: GEL, AGM, FLOODED, LITHIUM, PROGRAM
    • CHARGER VOLTAGE RANGE: 13.8V – 15.5V
    • FLOAT VOLTAGE RANGE: 13.0V – 13.8V
    • CHARGER CURRENT (USER SELECTABLE): 5/10/15/20/25/30/35/40/45/50A (DEFAULT 40A)
    • EQUALIZE VOLTAGE (FLOODED BATTERY): 15.5V
    • EQUALIZE CHARGING CURRENT: 10% OF BULK CURRENT SETTING
    • CHARGING CONTROL: 2 STAGE / 3 STAGE SELECTABLE (DEFAULT 3 STAGE)
    • DC OUTPUT BANK: SINGLE
    • CURRENT DRAW FROM CH1 WHEN NOT IN USE: < 50MA
    • BATTERY TEMPERATURE SETTING: LOW/ NORMAL/ HIGH (BATTERY TEMPERATURE SENSOR STANDARD)
    • EFFICIENCY: 95%
    • INPUT VOLTAGE: 14.5 – 45VOC
    • MAXIMUM INPUT: ≤ 23V INPUT, 500W (600W ALLOWABLE) ≥37.5V-45V INPUT, 750W (800W ALLOWABLE)
    • INPUT VOLTAGE: 10.5 – 16VDC / 21 – 32VDC
    • DIMENSIONS (H X W X D): 242MM X 172MM X 74MM
    • UNIT WEIGHT: 1.85 KG
    • SHIPPING WEIGHT: 2.17 KG
Out Of Stock
15% OFF
EPOWER EN31220

EPOWER EN31220

    FEATURES:

    • MULTISTAGE CHARGING: FULLY AUTOMATIC MULTISTAGE BATTERY CHARGER WITH THE ABILITY TO CHARGE 3 SEPARATE BATTERY BANKS.
    • SEPARATE BATTERY BANKS: ISOLATED CHARGING DESIGN WHERE BATTERY BANK ONE IS SEPARATE FROM BATTERY BANK TWO AND THREE.
    • PROGRAMMABLE: BATTERY BANK 1 CAN BE PROGRAMMED WITH A DIFFERENT CHARGE ALGORITHM OVER BANKS 2 AND 3.
    • CURRENT CONTROL: USER ADJUSTABLE CURRENT OUTPUT (E.G. DIAL THE 60AMP UNIT BACK TO RUN OFF A 1KVA GENERATOR).
    • SMART CHARGING: THE EPOWER 20A BATTERY CHARGER WILL REGULATE ITS OUTPUT BASED ON THE LOADS CONNECTED TO YOUR BATTERY BANKS.
    • WIDE AC INPUT RANGE: OPERATES ON BOTH 110V / 60HZ AND 240V / 50HZ.
    • LED DISPLAY: EASY TO USE “SET AND SELECT” MENU ALONG WITH SCROLLING CHARGER STATUS.
    • SILENT MODE: DISABLES THE COOLING FAN FOR TOTAL SILENT OPERATION AT NIGHT OR WHENEVER REQUIRED. ACTIVATION REDUCES CHARGE OUTPUT BY HALF AND LOCKS OUT FAN FOR 12 HOURS.
    • TEMPERATURE SENSOR: BATTERY TEMPERATURE SENSOR INCLUDED WITH 3 METER CABLE.
    • 5 YEAR WARRANTY FROM AN AUSTRALIAN COMPANY RENOWNED FOR CUSTOMER SUPPORT.
15% OFF
EPOWER EN31240

EPOWER EN31240

    FEATURES:

    • MULTISTAGE CHARGING: FULLY AUTOMATIC MULTISTAGE BATTERY CHARGER WITH THE ABILITY TO CHARGE 3 SEPARATE BATTERY BANKS.
    • SEPARATE BATTERY BANKS: ISOLATED CHARGING DESIGN WHERE BATTERY BANK ONE IS SEPARATE FROM BATTERY BANK TWO AND THREE.
    • PROGRAMMABLE: BATTERY BANK 1 CAN BE PROGRAMMED WITH A DIFFERENT CHARGE ALGORITHM OVER BANKS 2 AND 3.
    • CURRENT CONTROL: USER ADJUSTABLE CURRENT OUTPUT (E.G. DIAL THE 60AMP UNIT BACK TO RUN OFF A 1KVA GENERATOR).
    • SMART CHARGING: THE EPOWER 40A BATTERY CHARGER WILL REGULATE ITS OUTPUT BASED ON THE LOADS CONNECTED TO YOUR BATTERY BANKS.
    • WIDE AC INPUT RANGE: OPERATES ON BOTH 110V / 60HZ AND 240V / 50HZ.
    • LED DISPLAY: EASY TO USE “SET AND SELECT” MENU ALONG WITH SCROLLING CHARGER STATUS.
    • SILENT MODE: DISABLES THE COOLING FAN FOR TOTAL SILENT OPERATION AT NIGHT OR WHENEVER REQUIRED. ACTIVATION REDUCES CHARGE OUTPUT BY HALF AND LOCKS OUT FAN FOR 12 HOURS.
    • TEMPERATURE SENSOR: BATTERY TEMPERATURE SENSOR INCLUDED WITH 3 METER CABLE.


    SPECIFICATIONS:

    CHARGER OUTPUT

    • OUTPUT CURRENT (MAXIMUM) 40A
    • OUTPUT VOLTAGE RANGE
    • CHARGE 14.2 – 15.5 V
    • FLOAT 13.4 – 13.8 V
    • – EQUALIZE 16.0 V
    • CHARGING CONTROL FOUR STAGES (BULK/ABSORPTION/FLOAT/MAINTENANCE)
    • TWO STAGES (BULK/ABSORPTION)
    • CONSTANT POWER SUPPLY (PROGRAM SETTING)
    • PRIORITY BATTERY BANK CHARGING
    • DC OUTPUT BANK THREE (1 FULLY INDEPENDENT, 2 COMMON WITH DIODE ISOLATION)
    • SELECTABLE BATTERY TYPE GEL, AGM, FLOODED, LITHIUM, PROGRAM
    • STANDBY CURRENT < 2 MA

    CHARGER INPUT

    • AC INPUT VOLTAGE (NOMINAL) 90 TO 265 VAC
    • AC INPUT OPERATING RANGE 207-265 VAC (3.8 A MAX)90 – 125 VAC (7.7 A MAX)
    • AC INPUT FREQUENCY RANGE 47 – 63 HZ
    • POWER CONSUMPTION 700W (FULL LOAD)
    • POWER FACTOR CORRECTION YES
    • CHARGER EFFICIENCY > 82%

    PROTECTION AND FEATURES

    • REVERSE POLARITY YES, (WITH USER REPLACEABLE FUSE/S)
    • OVER CHARGE YES, UNIT SHUTDOWN
    • OVER TEMPERATURE YES, UNIT DE-RATED AND SHUTDOWN
    • OUTPUT SHORT CIRCUIT YES, (WITH USER REPLACEABLE FUSE/S)
    • COOLING FORCED AIR VENTILATION (THERMO CONTROLLED FAN)
    • TEMPERATURE SETTING HOT, NORMAL, COLD (NO SENSOR CONNECTED)
    • BATTERY TEMP SENSOR PORT RJ12 (STANDARD BATTERY TEMP. SENSOR SUPPLIED)

    DISPLAY

    • LCD DISPLAY (WITH BACK LIGHT) CHARGING STATUS, BATTERY VOLTAGE, OUTPUT CURRENT & FAULT CODES

    AC INPUT AND DC OUTPUT CONNECTION

    • AC INPUT CONNECTION IEC WITH SUPPLIED 1.2M POWER LEAD
    • DC OUTPUT CONNECTION HEAVY DUTY TERMINAL (3 BANKS) – PAN HEADS 6MM THREAD
    • DC OUTPUT GROUND SINGLE HEAVY DUTY COMMON GROUND STUD

    ENVIRONMENTAL AND OPERATING TEMPERATURE

    • STORAGE RANGE -40° TO 70° C
    • OPERATING RANGE -20° TO 60° C
    • HUMIDITY 5-95%, RELATIVE HUMIDITY NON-CONDENSING
    • INGRESS PROTECTION IP32 (BASIC DRIP PROOF IN VERTICAL ORIENTATION)

    BASE UNIT WEIGHT AND DIMENSIONS

    • WEIGHT: (KG) 2.6
    • DIMENSION: (MM) L X W X H 295 X 206 X 86

    REGULATORY COMPLIANCE

    • COMPLIES WITH AS/NZS 60335.2.29 INCLUDING AUSTRALIAN DEVIATIONS.
Out Of Stock
20% OFF
EPOWER EN31260

EPOWER EN31260

    FEATURES:

    • MULTISTAGE CHARGING: FULLY AUTOMATIC MULTISTAGE BATTERY CHARGER WITH THE ABILITY TO CHARGE 3 SEPARATE BATTERY BANKS.
    • SEPARATE BATTERY BANKS: ISOLATED CHARGING DESIGN WHERE BATTERY BANK ONE IS SEPARATE FROM BATTERY BANK TWO AND THREE.
    • PROGRAMMABLE: BATTERY BANK 1 CAN BE PROGRAMMED WITH A DIFFERENT CHARGE ALGORITHM OVER BANKS 2 AND 3.
    • CURRENT CONTROL: USER ADJUSTABLE CURRENT OUTPUT (E.G. DIAL THE 60AMP UNIT BACK TO RUN OFF A 1KVA GENERATOR).
    • SMART CHARGING: THE EPOWER 60A BATTERY CHARGER WILL REGULATE ITS OUTPUT BASED ON THE LOADS CONNECTED TO YOUR BATTERY BANKS.
    • WIDE AC INPUT RANGE: OPERATES ON BOTH 110V / 60HZ AND 240V / 50HZ.
    • LED DISPLAY: EASY TO USE “SET AND SELECT” MENU ALONG WITH SCROLLING CHARGER STATUS.
    • SILENT MODE: DISABLES THE COOLING FAN FOR TOTAL SILENT OPERATION AT NIGHT OR WHENEVER REQUIRED. ACTIVATION REDUCES CHARGE OUTPUT BY HALF AND LOCKS OUT FAN FOR 12 HOURS.
    • TEMPERATURE SENSOR: BATTERY TEMPERATURE SENSOR INCLUDED WITH 3 METER CABLE.


    SPECIFICATIONS:

    CHARGER OUTPUT

    • OUTPUT CURRENT (MAXIMUM) 60A

    OUTPUT VOLTAGE RANGE

    • CHARGE 14.2 – 15.5 V
    • FLOAT 13.4 – 13.8 V
    • – EQUALIZE 16.0 V
    • CHARGING CONTROL FOUR STAGES (BULK/ABSORPTION/FLOAT/MAINTENANCE)
    • TWO STAGES (BULK/ABSORPTION)
    • CONSTANT POWER SUPPLY (PROGRAM SETTING)
    • PRIORITY BATTERY BANK CHARGING
    • DC OUTPUT BANK THREE (1 FULLY INDEPENDENT, 2 COMMON WITH DIODE ISOLATION)
    • SELECTABLE BATTERY TYPE GEL, AGM, FLOODED, LITHIUM, PROGRAM
    • STANDBY CURRENT < 2 MA

    CHARGER INPUT

    • AC INPUT VOLTAGE (NOMINAL) 90 TO 265 VAC
    • AC INPUT OPERATING RANGE 207-265 VAC (5.9 A MAX)90-125 VAC (11.3 A MAX)
    • AC INPUT FREQUENCY RANGE 47 – 63 HZ
    • POWER CONSUMPTION 1050W (FULL LOAD)
    • POWER FACTOR CORRECTION YES
    • CHARGER EFFICIENCY > 82%

    PROTECTION AND FEATURES

    • REVERSE POLARITY YES, (WITH USER REPLACEABLE FUSE/S)
    • OVER CHARGE YES, UNIT SHUTDOWN
    • OVER TEMPERATURE YES, UNIT DE-RATED AND SHUTDOWN
    • OUTPUT SHORT CIRCUIT YES, (WITH USER REPLACEABLE FUSE/S)
    • COOLING FORCED AIR VENTILATION (THERMO CONTROLLED FAN)
    • TEMPERATURE SETTING HOT, NORMAL, COLD (NO SENSOR CONNECTED)
    • BATTERY TEMP SENSOR PORT RJ12 (STANDARD BATTERY TEMP. SENSOR SUPPLIED)

    DISPLAY

    • LCD DISPLAY (WITH BACK LIGHT) CHARGING STATUS, BATTERY VOLTAGE, OUTPUT CURRENT & FAULT CODES

    AC INPUT AND DC OUTPUT CONNECTION

    • AC INPUT CONNECTION IEC WITH SUPPLIED 1.2M POWER LEAD
    • DC OUTPUT CONNECTION HEAVY DUTY TERMINAL (3 BANKS) – PAN HEADS 6MM THREAD
    • DC OUTPUT GROUND SINGLE HEAVY DUTY COMMON GROUND STUD

    ENVIRONMENTAL AND OPERATING TEMPERATURE

    • STORAGE RANGE -40° TO 70° C
    • OPERATING RANGE -20° TO 60° C
    • HUMIDITY 5-95%, RELATIVE HUMIDITY NON-CONDENSING
    • INGRESS PROTECTION IP32 (BASIC DRIP PROOF IN VERTICAL ORIENTATION)

    BASE UNIT WEIGHT AND DIMENSIONS

    • WEIGHT: (KG) 4
    • DIMENSION: (MM) L X W X H 356 X 206 X 99

    REGULATORY COMPLIANCE

    • COMPLIES WITH AS/NZS 60335.2.29 INCLUDING AUSTRALIAN DEVIATIONS.
Out Of Stock
9% OFF
EPOWER EN32430

EPOWER EN32430

    FEATURES:

    • MULTISTAGE CHARGING: FULLY AUTOMATIC MULTISTAGE BATTERY CHARGER WITH THE ABILITY TO CHARGE 3 SEPARATE BATTERY BANKS.
    • SEPARATE BATTERY BANKS: ISOLATED CHARGING DESIGN WHERE BATTERY BANK ONE IS SEPARATE FROM BATTERY BANK TWO AND THREE.
    • PROGRAMMABLE: BATTERY BANK 1 CAN BE PROGRAMMED WITH A DIFFERENT CHARGE ALGORITHM OVER BANKS 2 AND 3.
    • CURRENT CONTROL: USER ADJUSTABLE CURRENT OUTPUT (E.G. DIAL THE 60AMP UNIT BACK TO RUN OFF A 1KVA GENERATOR).
    • SMART CHARGING: THE EPOWER 30A BATTERY CHARGER WILL REGULATE ITS OUTPUT BASED ON THE LOADS CONNECTED TO YOUR BATTERY BANKS.
    • WIDE AC INPUT RANGE: OPERATES ON BOTH 110V / 60HZ AND 240V / 50HZ.
    • LED DISPLAY: EASY TO USE “SET AND SELECT” MENU ALONG WITH SCROLLING CHARGER STATUS.
    • SILENT MODE: DISABLES THE COOLING FAN FOR TOTAL SILENT OPERATION AT NIGHT OR WHENEVER REQUIRED. ACTIVATION REDUCES CHARGE OUTPUT BY HALF AND LOCKS OUT FAN FOR 12 HOURS.
    • TEMPERATURE SENSOR: BATTERY TEMPERATURE SENSOR INCLUDED WITH 3 METER CABLE.


    SPECIFICATIONS:

    CHARGER OUTPUT

    • OUTPUT CURRENT (MAXIMUM) 30A

    OUTPUT VOLTAGE RANGE

    • CHARGE 28.4 – 31.0V
    • FLOAT 26.8 – 27.6V
    • – EQUALIZE 32.0V
    • CHARGING CONTROL FOUR STAGES (BULK/ABSORPTION/FLOAT/MAINTENANCE)
    • TWO STAGES (BULK/ABSORPTION)
    • CONSTANT POWER SUPPLY (PROGRAM SETTING)
    • PRIORITY BATTERY BANK CHARGING
    • DC OUTPUT BANK THREE (1 FULLY INDEPENDENT, 2 COMMON WITH DIODE ISOLATION)
    • SELECTABLE BATTERY TYPE GEL, AGM, FLOODED, LITHIUM, PROGRAM
    • STANDBY CURRENT < 2 MA

    CHARGER INPUT

    • AC INPUT VOLTAGE (NOMINAL) 90 TO 265 VAC
    • AC INPUT OPERATING RANGE 207-265 VAC (5.9 A MAX) 90-125 VAC (11.3 A MAX)
    • AC INPUT FREQUENCY RANGE 47 – 63 HZ
    • POWER CONSUMPTION 1050W (FULL LOAD)
    • POWER FACTOR CORRECTION YES
    • CHARGER EFFICIENCY > 82%

    PROTECTION AND FEATURES

    • REVERSE POLARITY YES, (WITH USER REPLACEABLE FUSE/S)
    • OVER CHARGE YES, UNIT SHUTDOWN
    • OVER TEMPERATURE YES, UNIT DE-RATED AND SHUTDOWN
    • OUTPUT SHORT CIRCUIT YES, (WITH USER REPLACEABLE FUSE/S)
    • COOLING FORCED AIR VENTILATION (THERMO CONTROLLED FAN)
    • TEMPERATURE SETTING HOT, NORMAL, COLD (NO SENSOR CONNECTED)
    • BATTERY TEMP SENSOR PORT RJ12 (STANDARD BATTERY TEMP. SENSOR SUPPLIED)

    DISPLAY

    • LCD DISPLAY (WITH BACK LIGHT) CHARGING STATUS, BATTERY VOLTAGE, OUTPUT CURRENT & FAULT CODES

    AC INPUT AND DC OUTPUT CONNECTION

    • AC INPUT CONNECTION IEC WITH SUPPLIED 1.2M POWER LEAD
    • DC OUTPUT CONNECTION HEAVY DUTY TERMINAL (3 BANKS) – PAN HEADS 6MM THREAD
    • DC OUTPUT GROUND SINGLE HEAVY DUTY COMMON GROUND STUD

    ENVIRONMENTAL AND OPERATING TEMPERATURE

    • STORAGE RANGE -40° TO 70° C
    • OPERATING RANGE -20° TO 60° C
    • HUMIDITY 5-95%, RELATIVE HUMIDITY NON-CONDENSING
    • INGRESS PROTECTION IP32 (BASIC DRIP PROOF IN VERTICAL ORIENTATION)

    BASE UNIT WEIGHT AND DIMENSIONS

    • WEIGHT: (KG) 4
    • DIMENSION: (MM) L X W X H 356 X 206 X 99

    REGULATORY COMPLIANCE

    • COMPLIES WITH AS/NZS 60335.2.29 INCLUDING AUSTRALIAN DEVIATIONS.
14% OFF